Can
sense the card but the door lock doesn’t work?
 |
Please check whether there is power supply on the
proximity reader and the electric lock
|
|
 |
If it is okay, please check the electric lock power
supply reader
and whether the connecting points are correct.
|
|
 |
Is the DENY light (yellow light) on? Check if
the card
are being registered.
|
|
 |
Continuous proximity. Please remove the card
from
proximity area then try again.
|
|
 |
Please check whether the door opening mode is
correct. |
System
password is entered but cannot enter into various functional
selection of the setting mode?
|
 |
Incomplete
input of command password, please
check
reader
whether
the following format has been entered:
#XXXX#
(XXXX
represents system password), or
first press
“*”
then input effective command password #XXXX#.
|
|
 |
Bad wire arrangement
which will affect press key data.
Please
confirm that the power supply wire and the
control wire has been
arranged to the space at the
back
of the display screen (this is the wire
arrangement
area of this equipment) in order to avoid
the wires pressing
on
the PC board causing bad
contact, short circuit and
interference.
|
How
to stop anti-damage activation or duress alarm activation?
|
 |
Remedy : Enter into
the system setting mode or open the door.
|
What
is the operation of the door sensor detection (reed switch)?
|
 |
Remedy
: If the door sensor detection function is being set at ON
(for
detail, refer to item 7 of the setting mode functional
selection
in the manual) and if the door is not closed
within
30 seconds, then the anti-damage output function
will
be executed.
|
|
|
|
| |
|