A N.C. door position output point
B N.C. & N.O. door position output points
D Dead bolt lock specially for automatic
door
For example: SL-100B is a dead bolt
lock
which has both N.C. & N.O.
door position
output points
Note:
SL-100 has its own micro-computer
control and detection. It is strongly
suggested to use its own door open
point (N.O. point) to open door and do
not turn its power off (N.C. point) to
open door.
Power supply: DC 12V
Operation current : 900mA; Holding current: 330mA
Fail-safe type and MOV surge protection.
Built-in door open or door close state detection output point (500mA: N.C./ N.O.).
Suitable for all types of 180° door.
Door lock delay time: 0/ 2.5/ 5/ 9 seconds available to set.
Built-in photo couplers door open push button input contact. Door will lock again automatically when door is not open within 5 seconds.