A N.C. door position output point B Door position detection and bolt position (N.C. & N.O.) output points
Example: SL-130B has door position detection
and bolt position (N.C. & N.O.) output points.
Please note that this electric lock has an oval
cylinder and its width is 5.8cm. Therefore, the best
position to install is at the center of the door leaf
(not door frame). Please refer to installation
diagram.
Power Supply: DC12V
Current: 0mA; Operation current : 880mA; Holding current: 250mA
Adjustable fail-safe (power to lock) or fail-secure (power to open).
Adjustable to fail-secure (power to open) for high security places. Adjustable to fail-safe (power to lock) for public places.
Built-in door open or door close state detection output point (500mA: N.C./ N.O.).
Suitable for 180° door.
Adjustable to fail-secure (power to open) to achieve long unlock state function.
Built-in oval cylinder as unlocking device. Use of oval cylinder to unlock when power cut occurred or during emergency.
Built-in photo couplers door open push button input contact. Door will lock again automatically when door is not open within 5 seconds.